Thread: EX Alarm. Results 1 to 1 of 1. We had the machine moved. The door slammed, the key hit the door lock switch hard and out of alignment. Smashing the switch. When we ran new electric to this machine and powered it up the door lock switch would not work. I replaced the switch with a Mori switch. We still could not get the machine out of an E-stop type of alarm. Fanuc did not have any so we had it rebuilt by IRC.

Now The door lock sequence starts to work when powering up the machine but when it tells you to open and close the door i get the EX alarm. Does anyone have any ideas.

mori seiki ex alarm codes

Need help! Replies: 4 Last Post:PM. Alarm [] D Replies: 2 Last Post:PM. Replies: 1 Last Post:AM. Replies: 6 Last Post:PM. The time now is PM. All rights reserved.

White claw colored tabs meaning

This website uses cookies We use cookies to optimize our website for you and to be able to improve it continuously. By clicking the "Agree" button, you expressly agree to the use of cookies. For further information on cookies, please refer to our privacy policy. More infomations about the cookies and further configurations.Forum Rules.

This website or its third-party tools process personal data e. To learn more, please refer to the cookie policy.

Ktor writing tests

In case of sale of your personal information, you may opt out by sending us an email via our Contact Us page. To find out more about the categories of personal information collected and the purposes for which such information will be used, please refer to our privacy policy.

You accept the use of cookies or other identifiers by closing or dismissing this notice, by scrolling this page, by clicking a link or button or by continuing to browse otherwise. The latest industry news—straight to your inbox. Sign up for our eNewsletter now to stay in-the-know. We'll bring you the most relevant peer-to-peer conversations happening in the trade and tips and tricks to help you get the job done. Invalid email. This is required. Login to Your Account. Remember Me? Register Forgot password?

What's New? Results 1 to 6 of 6. Thread: Fanuc alarm Thread Tools Show Printable Version. Fanuc alarm Good afternoon, We have a Mori Seiki that has been running fine lately. We have just input a programme number to be sent from the shop floor computer, pressed the 'read' soft key, and an alarm has appeared: clear all memory I have tried deleting single programmes but it says 'can not edit'. I have tried taking the bold step of deleting all programmes, but when I press execute it sems not to register.

My key is turned to edit and my mode selector is on edit. I have tried isolating machine but alam will not budge. Any ideas what the problem is and how I can resolve it guys? You have a memory corruption, caused by the control reading in an incomplete program or something The procedue for correcting this is the clear the program memory, not by just pressing delete programs as you have done, but to do a memory clear on power up.

The fanuc yellow book should give you the procedure in the appendix about alarms Howeverif your machine has macros in the memory to do tool changes or run bar feeders as ours have, then you need to make a record of what these macros are because the memory clear will delete these as well even if they are protected from a normal program delete.

I agree with Boris that if you still have the ability to backup the programs do so. They will however as Boris stated be deleted when doing a master clear. First off what model Fanuc control are you using? This will determine the procedure in which you clear the memory and also the exact parameters to lock and unlock the and programs.

Since you said it is alarm I am going to ass u me that you are on a Oseries control. First backup your control.Forum Rules. This website or its third-party tools process personal data e.

To learn more, please refer to the cookie policy. In case of sale of your personal information, you may opt out by sending us an email via our Contact Us page. To find out more about the categories of personal information collected and the purposes for which such information will be used, please refer to our privacy policy.

You accept the use of cookies or other identifiers by closing or dismissing this notice, by scrolling this page, by clicking a link or button or by continuing to browse otherwise. The latest industry news—straight to your inbox. Sign up for our eNewsletter now to stay in-the-know.

We'll bring you the most relevant peer-to-peer conversations happening in the trade and tips and tricks to help you get the job done. Invalid email. This is required.

382136138-Alarmas-EX-ALL-MoriSeiki.doc

Login to Your Account. Remember Me? Register Forgot password? What's New? Mori Seiki Tool change alarm EX Results 1 to 7 of 7. Thread: Need Help!!! Thread Tools Show Printable Version. Need Help!!! Mori Seiki Tool change alarm EX I am extremely frustrated and I cant find a person in the world with the answer to my problem. My Mori Seiki dealer support eng. I purchased the machine in "good working condition" but as it turns out, I have a big mess on my hands.

Ps2 controller buttons layout

I have been spending time and money since because I am in too deep. I have all of the drives repaired, switches and wires repaired and the machine is finally running. The machine has a 12 pot tool changer but only tools can be called.

My friend purchased the sister to this machine and he has the identical problem except his machine ran from day one.Forum Rules. This website or its third-party tools process personal data e.

To learn more, please refer to the cookie policy.

Fanuc Alarm Codes List

In case of sale of your personal information, you may opt out by sending us an email via our Contact Us page. To find out more about the categories of personal information collected and the purposes for which such information will be used, please refer to our privacy policy.

You accept the use of cookies or other identifiers by closing or dismissing this notice, by scrolling this page, by clicking a link or button or by continuing to browse otherwise. The latest industry news—straight to your inbox. Sign up for our eNewsletter now to stay in-the-know. We'll bring you the most relevant peer-to-peer conversations happening in the trade and tips and tricks to help you get the job done. Invalid email. This is required. Login to Your Account. Remember Me? Register Forgot password?

What's New? Results 1 to 14 of Thread Tools Show Printable Version. Stops the machine cold and have to reboot. I'm running a 1" 12L14 steel bar job. A couple of the sticks are not the straightest and am dealing with some vibration.

Using a Trusty Cook liner and Spego bar feed.

Dove vengono salvati gli screen fatti in cs:s?

I'm wondering if the vibration can be setting this off. There is a proximity sensor that reads the passing of three notches cut out of the brake disc hub and is labeled spindle speed sensor in the book. It's connected directly to the PLC.

I see it's mounted very close and thought tomorrow I'd move it away a bit and see if it still reads okay. After my program stalled a couple times in the higher speed sections capped at rpm I pulled the bar out and ran it without stock and had no problems over what was three, two minute runs.

CNC Alarms – Complete CNC Alarms Error Code Lists

With it being so intermittent thus far I'm reluctant to swear to it that I've solved the problem. I mean, was running it without stock and eliminating the vibration really fixing the problem, or was the machine simply playing nice for the time being?

Hard to tell. I can't find squat about this error either here on the www. Anyone with past experience or ideas what I might be up against?Forum Rules. This website or its third-party tools process personal data e.

mori seiki ex alarm codes

To learn more, please refer to the cookie policy. In case of sale of your personal information, you may opt out by sending us an email via our Contact Us page. To find out more about the categories of personal information collected and the purposes for which such information will be used, please refer to our privacy policy.

You accept the use of cookies or other identifiers by closing or dismissing this notice, by scrolling this page, by clicking a link or button or by continuing to browse otherwise. The latest industry news—straight to your inbox. Sign up for our eNewsletter now to stay in-the-know. We'll bring you the most relevant peer-to-peer conversations happening in the trade and tips and tricks to help you get the job done. Invalid email. This is required. Login to Your Account. Remember Me?

Register Forgot password? What's New? Results 1 to 3 of 3. Thread Tools Show Printable Version. Head one works normally. The alarm description in the book simply says "Sequence program error" and "contact Mori Seiki". Well, I have had some people look at it, and I've talked to a few people at Mori and tried Fanucbut no one seems to be able to help too much so far, so I thought I would test your knowledge here collectively. Anyway, looking at the ladder on the machine, the PER is definitely active, so I started there.

Following the ladder "backwards" from the PER coil leads me to the contact R When looking at that rung, the contact R Now then, if you're following along, the rung of the ladder I'm looking at seems to have a function block in it. I don't know how to decipher this function block.

The only thing I have noticed is that when I power up the machine and there is no alarm, the data in the function block shows one thing, and when we create the alarm by pressing the button, the data populates to something else.

If you could help me understand how the function blocks work, or what they are trying to tell me in this case, I would much appreciate it. Specifically in this case I have 5 boxes left to right on the rung which are labeled as follows: 1.

Problem was resolved. Hey mate, do you remember the solution? Bookmarks Bookmarks Digg del. I agree to receive emails from Practical Machinist containing industry news and updates from Practical Machinist and its sponsors.

mori seiki ex alarm codes

You may unsubscribe at any time.Also I can not turn control off with PB. Link from okela. Function tells what the g-code does, Notes gives a little more information such as the parameters, and Tutorial is a link if any to a tutorial that uses G-Wizard Editor to teach how to use the g-code.

The door slammed, the key hit the door lock switch hard and out of alignment. Otherwise, electrical shocks, breakdown, and blowout may occur. I replaced the switch with a Mori switch. The alarm will show which axis is causing the problem. If any drives have alarm then the odds are that it is internal in the drive. It came about after trying to tool change.

Mori seiki ex alarm codes

I have a fanuc turret spindle drive with a 12 alarm that will not clear with pwr. Confirmed link from www. The same signals have been made valid for different pins in parameters 20 or Refer to diagnostics or for details. CMX 50 U. I had a battery failure and lost all parameters, reloaded everything via Rs and the end result is this Ex Soft overtravel machine alarm occurs when zero returning: There are 3 ways to get by this in order to complete the zero return.

Scribd is the world's largest social reading and publishing site. To replace the battery, see the procedure described in Section 2. Position detection system fault in the n—th axis axis 1—8 pulse coder disconnection alarm.

I am told that it is a double parameter issue and I need a password to be able to access and rewrite the "D" parameters.

Tone shift in sonnet 18

NLX Jog it to the center of travel. This alarm occurs when the n-th axis axis is in one of the conditions listed below Digital servo system alarm. This alarm occurs when the n—th axis axis 1—8 is in one of the conditions listed below.

Electron Z32 Alarms. Software limit positions are set with parameters. Remedy - Execute 1st reference position return. To determine the exact cause, you must go through the process of elimination. Change the servo amplifier. No comment but a hopeful question.

mori seiki ex alarm codes

Correct the tape. Confirmed link from okela. Complete lists of Doosan alarm codes.Check the monitor circuit. Check the motor interruption circuit. Check the turret output driver or clamp signal. Index the station manually. Reset the parameter. This error is caused when a phase-A signal is output twice in a row. Either the proximity switch for the phase-B counter is defective or it is improperly adjusted.

This error is caused when a phase-B signal is output twice in a row. Either the proximity switch for the phase-A counter is defective or it is improperly adjusted. Either the proximity switch for the counter is defective or it is improperly adjusted.

Either the home position detection switch or the phase-A count switch is defective or they are improperly adjusted. Either the home position detection switch or the phase -A count switch is defective or they are improperly adjusted.

Possible cause is broken piping or motor failure. Possible cause is failure in the pressure switch or the magnet. Please contact your dealer. Specify M39 in a single block. Check out www. Go to www. Learn more about Scribd Membership Home. Read free for days Sign In.